• 已选条件:
  • × Hao Liu
  • × 期刊论文
  • × Energies
 全选  【符合条件的数据共:9条】

Energies,2014年

Kai Yang, Hongguang Zhang, Songsong Song, Fubin Yang, Hao Liu, Guangyao Zhao, Jian Zhang

LicenseType:CC BY |

预览  |  原文链接  |  全文  [ 浏览:2 下载:0  ]    

Energies,2017年

Zhongping Yang, Xianjin Huang, Hao Liu, Fei Lin

LicenseType:Unknown |

预览  |  原文链接  |  全文  [ 浏览:0 下载:0  ]    

Energies,2022年

Guoxiong Mei, Xiaoyan Yang, Zijian Yang, Guosheng Jiang, Wenbing Wu, Hao Liu

LicenseType:Unknown |

预览  |  原文链接  |  全文  [ 浏览:0 下载:0  ]    

Energies,,13,38682020年

Qiang Chen, Ye Zhou, Shuiguang Tong, Zheming Tong, Hao Liu, Jianfeng Ma, Yunzhe Li

LicenseType:Unknown |

预览  |  原文链接  |  全文  [ 浏览:0 下载:0  ]    

A super high-head Francis turbine with a gross head of nearly 700 m was designed with computational fluid dynamics (CFD) simulation and laboratory tests. Reduced-scale (1:3.7) physical and numerical models of the real-scale prototype were created to investigate the hydraulic performance. According to the CFD analysis, a strong rotor–stator interaction (RSI) between guide vanes and runner blades is observed as a result of the high-speed tangential flow towards runner created by the super high water head as well as the small gaps between the radial blades. At the designed best efficiency point (BEP), there is no significant flow recirculation inside the flow passage and minor loss occurs at the trailing edge of the stay vanes and guide vanes. Maximum velocity is observed at runner inlets due to flow acceleration through the narrow passages between the guide vanes. The elbow-shaped draft tube gradually decreases the flow velocity to keep the kinetic energy loss at a minimum. The laboratory test was conducted on a reduced-scale physical model to investigate the pressure pulsations and guide vane torque (GVT) under variable-discharge configurations, which are key concerns in the design of a high head turbine. Pressure sensor networks were installed at the inlet pipe, vaneless space and draft tube, respectively. The most intense pressure variation occurs at the inlet pipe and elbow at 0.04–0.2 GVOBEP and 1.5–1.8 GVOBEP with a low frequency about 0.3 times of the runner frequency, while the vibration in vaneless zone performs stable with the blade passing frequency caused by RSI. The GVT shows a declining trend and then keeps stable as GVOs increases at synchronized condition. For the misaligned conditions, the torque of adjacent guide vanes differs a lot except at the synchronous angle and maximum absolute value at least doubles than the synchronized condition.

    Energies,2013年

    Sigrid Adriaenssens, Hao Liu, Mariam Wahed

    LicenseType:CC BY |

    预览  |  原文链接  |  全文  [ 浏览:55 下载:17  ]    

    Energies,2015年

    Zhicheng Shi, Hongguang Zhang, Hao Liu, Haitao Lu, Jiazheng Li, Xiang Gao

    LicenseType:CC BY |

    预览  |  原文链接  |  全文  [ 浏览:12 下载:11  ]