All season heat pipe system.
solar;passive;heat pipe
Adrienne Marie Parsons
University:University of Louisville
Department:Mechanical Engineering
关键词: solar;    passive;    heat pipe;   
Others  :  https://ir.library.louisville.edu/cgi/viewcontent.cgi?article=4481&context=etd
美国|英语
来源: The Universite of Louisville's Institutional Repository
PDF
【 摘 要 】
Our energy choices impact the earth’s natural systems and climate. As this becomes increasingly important, the need for decreasing our energy usage is essential. Conventional passive solar systems can significantly reduce the heating load. Similarly, passive ambient energy systems, such as ventilation and sky radiation, can reduce cooling loads. However, the integration of passive heating and cooling systems in the same building and the benefits of actively controlling these otherwise passive systems to maximize annual energy savings has largely been unexplored. This study first evaluates the building cooling capacity of sky radiation, which was previously identified to have the greatest cooling potential among common ambient sources for climates across the U.S., and the design parameters of the system. Next, the study develops and varies the control strategies of a passive heating and cooling system with the objective of maximizing annual energy and cost savings. The systems were simulated with thermal networks using Matrix Laboratory (MATLAB), a computer software package. Nodal temperatures were simultaneously solved as functions of time using Typical Meteorological Year (TMY3) weather data. Auxiliary heating and cooling were added as needed to limit room temperature to a maximum of 23.9 ˚C and minimum of 18.3 ˚C. Results were compared to a Louisville baseline with LRR = 10 W/m2K, horizontal radiator and one cover, which provided an annual sky fraction (fraction of cooling load provided by sky radiation) of 0.855. A decrease to 0.852 was found for an increase in radiator slope to 20˚, and a drop to 0.832 for 53˚ slope (latitude + 15˚, a typical slope for solar heating). These drops were associated with increases in average radiator temperature by 0.73˚C for 20˚ and 1.99˚C for 53˚. A 30% decrease in storage capacity caused a decrease in sky fraction to 0.843. LRR and thermal storage capacity had strong effects on performance. Radiator slope had a surprisingly small impact, considering that the view factor to the sky at 53˚ tilt is less than 0.5. Chapter 3 expanded on and analyzed the design of the windscreen for the sky radiator used for cooling as well as the effects of implementing the heat pipe augmented sky radiator to varying climates. When applying a windscreen of polyethylene, which is mostly transparent to long-wave radiation, a drawback of polyethylene is its susceptibility to degradations of the optical properties. Sky fractions of 100% were possible in cities with small cooling loads (Rock Springs,
【 预 览 】
附件列表
Files Size Format View
All season heat pipe system. 3630KB PDF download
  文献评价指标  
  下载次数:4次 浏览次数:12次