学位论文详细信息
Microfluidic H2/O2 fuel cells for contaminant and electrode analysis
alkaline fuel cell;reference electrode;single electrode plots;silver (Ag) cathode;electrode degradation
Naughton, Matt ; Kenis ; Paul J.A.
关键词: alkaline fuel cell;    reference electrode;    single electrode plots;    silver (Ag) cathode;    electrode degradation;   
Others  :  https://www.ideals.illinois.edu/bitstream/handle/2142/24356/Naughton_Matt.pdf?sequence=1&isAllowed=y
美国|英语
来源: The Illinois Digital Environment for Access to Learning and Scholarship
PDF
【 摘 要 】

Alkaline fuel cells (AFCs) are promising power sources due to superior cathode kinetics as compared to acidic media and the ability to use inexpensive non-noble metal catalysts.However, carbonate formation from carbon dioxide in air has long been considered a significant hurdle for liquid electrolyte-based AFC technologies.Carbonate formation consumes hydroxyl anions, which leads to (i) reduced electrode performance if formed salts precipitate from solution and (ii) lowered electrolyte conductivity, which reduces cell performance and operating lifetime.We have used a microfluidic H2/O2 fuel cell as an analytical platform to determine the effects of the carbonate formation problem in alkaline fuel cells.The microfluidic fuel cell has modular components that can easily be swapped to test electrodes, electrolyte, or other aspects of the fuel cell.A reference electrode placed at the outlet allows for individual electrode analysis, which is not normally possible in conventional membrane-based fuel cells.In this thesis, it is demonstrated that AFC performance can be resilient to a broad range of carbonate concentrations.Furthermore, the effects of carbonate formation rates on projected AFC operational lifetime are determined.A quantitative method to analyze individual electrode performance using single electrode plots and the two parameters Rohmic and Vkinetic is also developed.Results demonstrated that losses from both electrodes are substantial in an alkaline fuel cell, and that ohmic and mass transport losses are shown to only significantly affect Rohmic.IR-corrections were used to isolate individual kinetic and mass transport losses at each electrode within the operating fuel cell.These findings demonstrate great potential to broaden the scope of fuel cell research.

【 预 览 】
附件列表
Files Size Format View
Microfluidic H2/O2 fuel cells for contaminant and electrode analysis 3200KB PDF download
  文献评价指标  
  下载次数:35次 浏览次数:33次