学位论文详细信息
Fast and Motion Robust Dynamic R2* Reconstruction for Functional MRI.
Iterative Reconstruction;R2*;FMRI;Electrical Engineering;Engineering;Electrical Engineering: Systems
Olafsson, Valur ThorSolo, Victor ;
University of Michigan
关键词: Iterative Reconstruction;    R2*;    FMRI;    Electrical Engineering;    Engineering;    Electrical Engineering: Systems;   
Others  :  https://deepblue.lib.umich.edu/bitstream/handle/2027.42/63702/volafsso_1.pdf?sequence=1&isAllowed=y
瑞士|英语
来源: The Illinois Digital Environment for Access to Learning and Scholarship
PDF
【 摘 要 】

Blood oxygen level dependent (BOLD) functional MRI (fMRI) imaging is the most common way of imaging neuronal activity in humans using MRI.The BOLD contrast is directly related to changes in vascular physiology associated with neuronal activity and can be directly linked to changes in cerebral blood volume, blood flow and metabolic rate of oxygen.Conventional BOLD imaging is done by reconstructing T2*-weighted images.T2∗-weighted images are unitless and even though they measure the magnitude of the BOLD contrast they are still nonquantifiable in terms of thevascular physiology.An alternative approach is to reconstruct R2∗ maps which are quantifiable and can be directly linked to the vascular changes during activation.However, conventional R2∗ mapping involves long readouts and generally ignores relaxation and off-resonance during readout.Since fMRI data is usually acquired over a course of several minutes, where the same image volume is collected multiple times, it is important for the time series of each pixel to only reflect changes due to neuronal activity.However, BOLD imaging suffers from temporal drift/fluctuations and subject motion which can confound the findings.Conventionally, a field map is collected at the start of the fMRI study to correct for off-resonance, ignoring any possible changes in it due to either drift or motion.Here we propose a new fast and motion robust R2∗ iterative reconstruction that jointly reconstructs initial magnetization and field maps along with the R2∗ changes, for all time frames in fMRI.To accelerate the algorithm we propose to linearize the MR signal model, enabling the use of fast regularized iterative reconstruction methods.The regularizer was designed to account for the different resolution properties of both R2∗ and field maps and provide uniform spatial resolution.

【 预 览 】
附件列表
Files Size Format View
Fast and Motion Robust Dynamic R2* Reconstruction for Functional MRI. 1105KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:22次