Wavefront assessment and correction of the rat eye for two photon excitation therapies
rat model;two photon excitation photodynamic therapy;contact lenses;optical quality;spherical aberration;Hartmann Shack wavefront sensing;confocal scanning laser ophthalmoscopy;adaptive optics;age related macular degeneration
Andrews, Ianaffiliation1:Faculty of Science ; advisor:Campbell, Melanie ; Campbell, Melanie ;
University of Waterloo
关键词: spherical aberration;    age related macular degeneration;    rat model;    Master Thesis;    optical quality;    Hartmann Shack wavefront sensing;    adaptive optics;    confocal scanning laser ophthalmoscopy;    two photon excitation photodynamic therapy;    contact lenses;   
Others  :  https://uwspace.uwaterloo.ca/bitstream/10012/10748/1/Andrews_Ian.pdf
瑞士|英语
来源: UWSPACE Waterloo Institutional Repository
PDF
【 摘 要 】

Photodynamic therapy (PDT) is a treatment in which light excites a photosensitive drug to produce oxygen radicals that kills nearby cells. Today, PDT’s is most commonly used application is for the destruction of cancerous tumor cells in humans, however it can also be used to treat the eye disease, age-related macular degeneration (AMD). One-photon excitation PDT treatment of AMD has not been found to successfully improve vision quality due to the revascularization in the retina which occurs post-treatment. Two-photon excitation (TPE) has been explored as an alternative because it may prevent revascularization of the retina post-treatment and provides more precise treatment localization. The rat eye has been selected as the optical model for testing TPE of a photosensitive drug, however the rat eye suffers from poor tear film quality and large optical aberrations requiring adaptive optics to improve retinal image quality and the probability of TPE. In vivo testing of the excitation of a photosensitive drug via TPE is an important step towards successful treatment of AMD in the human eye.In this thesis, the design of an adaptive optics scanning laser ophthalmoscope for two photon light delivery is outlined, retinal images and wavefront error correction of the rat eye using a Xinetics 37-channel deformable mirror are presented. The extension of a schematic rat eye model to include a contact lens and tear lens predicts improved image quality at the retina for a larger pupil size. During the course of this project, changes in refractive error and retinal image quality while using different contact lenses were observed. Based on the model and experimental observations, the use of rigid contact lenses was shown toimprove retinal image quality of the rat eye and therefore the probability of TPE in the rat eye, prior to the use of adaptive optics.

【 预 览 】
附件列表
Files Size Format View
Wavefront assessment and correction of the rat eye for two photon excitation therapies 5355KB PDF download
  文献评价指标  
  下载次数:28次 浏览次数:19次