科技报告详细信息
Alternate High Efficiency Particulate Air (HEPA) Filtration System. Phase IIA Final Report, September 29, 1999-September 30, 2002.
Bishop, B. ; Goldsmith, R. ; Nielsen, K. ; Paquette, P.
Technical Information Center Oak Ridge Tennessee
关键词: Filtration;    Particulates;    Air filters;    Efficiency;    Nuclear facilities;   
RP-ID  :  DE2004834563
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

In Phase IIA of this project, CeraMem has further developed and scaled up ceramic HEPA filters that are appropriate for use on filtration of vent gas from HLW tanks at DOE sites around the country. This work included procuring recrystallized SiC monoliths, developing membrane and cement materials, and defining a manufacturing process for the production of prototype full sizes HEPA filters. CeraMem has demonstrated that prototype full size filters can be manufactured by producing 9 full size filters that passed DOP aerosol testing at the Oak Ridge Filter Test Facility. One of these filters was supplied to the Savannah River Technical Center (SRTC) for process tests using simulated HLW tank waste. SRTC has reported that the filter was regenerable (with some increase in pressure drop) and that the filter retained its HEPA retention capability. CeraMem has also developed a Regenerable HEPA Filter System (RHFS) design and acceptance test plan that was reviewed by DOE personnel. The design and acceptance test plan form the basis of the system proposal for follow-on work in Phase IIB of this project.

【 预 览 】
附件列表
Files Size Format View
DE2004834563.pdf 7697KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:29次