科技报告详细信息
Hydrolasing of Contaminated Underwater Basin Surfaces at the Hanford K Area.
Chronister, G. B. ; Umek, A. M.
Technical Information Center Oak Ridge Tennessee
关键词: Hydrolasing;    Decontamination;    Hanford Reservation;    Concretes;    Radioactive waste management;   
RP-ID  :  DE2005852224
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

This paper discusses selecting and implementing hydrolasing technology to reduce radioactive contamination in preparing to dispose of the K Basins: two highly contaminated concrete basins at the Hanford Site. A large collection of spent nuclear fuel stored for many years underwater at the K Basins has been removed to stable, dry, safe storage. Remediation activities have begun for the remaining highly contaminated water, sludge, and concrete basin structures. Hydrolasing will be used to decontaminate and prepare the basin structures for disposal. The DOE Richland Operations Office (RL) has given Fluor Hanford Inc./Fluar Government Group (Fluor) the task of preparing Hanford's K Basins for decontamination and disposal. Prior to dewatering, hydrolasing will be used to decontaminate the basin surfaces to prepare them for disposal. By removing highly contaminated surface layers of concrete, hydrolasing will be used to meet the dose objectives for protecting workers and complying with regulations for transporting demolition debris. Fluor has innovated, tested, and planned the application of the hydrolasing technology to meet the challenge of decontaminating highly radioactive concrete surfaces underwater. Newly existing technology is being adapted to this unique challenge.

【 预 览 】
附件列表
Files Size Format View
DE2005852224.pdf 4320KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:22次