科技报告详细信息
High Resolution Imaging with AEOS.
Patience, J. ; Macintosh, B. A. ; Max, C. E.
Technical Information Center Oak Ridge Tennessee
关键词: Adaptive optics;    Astronomy;    Telescopes;    Hawaii;    AEOS(Advanced Electro-optical system);   
RP-ID  :  DE200515013379
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The U. S. Air Force Advanced Electro-Optical System (AEOS) which includes a 941 actuator adaptive optics system on a 3.7m telescope has recently been made available for astronomical programs. Operating at a wavelength of 750 nm, the diffractionlimited angular resolution of the system is 0 in .04; currently, the magnitude limit is V-7 mag. At the distances of nearby open clusters, diffraction-limited images should resolve companions with separations as small as 4-6 AU - comparable to the Sun- Jupiter distance. The ability to study such close separations is critical, since most companions are expected to have separations in the few AU to tens of AU range. With the exceptional angular resolution of the current AEOS setup, but restricted target magnitude range, we are conducting a companion search of a large, well-defined sample of bright early-type stars in nearby open clusters and in the field. Our data set will both characterize .this relatively new adaptive optics system and answer questions in binary star formation and stellar X-ray activity. We will discuss our experience using AEOS, the data analysis involved, and our initial results.

【 预 览 】
附件列表
Files Size Format View
DE200515013379.pdf 3231KB PDF download
  文献评价指标  
  下载次数:32次 浏览次数:35次