科技报告详细信息
Borehole Flow and Horizontal Hydraulic Conductivity with Depth at Well ER-12-4 (Letter Report).
Oberlander, P. L. ; Russell, C. E.
Technical Information Center Oak Ridge Tennessee
关键词: Boreholes;    Water wells;    Flow rate;    Flowmeters;    Hydraulic conductivity;   
RP-ID  :  DE2006862130
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

Borehole flow and fluid temperature during pumping were measured at well ER-12-4 at the Nevada Test Site in Nye County, Nevada. This well was constructed to characterize the carbonate aquifer. The well is cased from land surface to the total depth at 1,132 m (3,713 ft bgs) below ground surface (bgs). The screened section of the well consists of alternating sections of slotted well screen and blank casing from 948 to 1,132 m bgs (3,111 to 3,713 ft bgs). Borehole flow velocity (LT-1) with depth was measured with an impeller flowmeter from the top of the screened section to the maximum accessible depth while the well was pumped and under ambient conditions. A complicating factor to data interpretation is that the well was not filter packed and there is upward and downward vertical flow in the open annulus under ambient and pumping conditions. The open annulus in the well casing likely causes the calculated borehole flow rates being highly nonrepresentative of inflow from the formation. Hydraulic conductivities calculated under these conditions would require unsupportable assumptions and would be subject to very large uncertainties. Borehole hydraulic conductivities are not presented under these conditions.

【 预 览 】
附件列表
Files Size Format View
DE2006862130.pdf 3091KB PDF download
  文献评价指标  
  下载次数:31次 浏览次数:19次