In May 2004 alpha contamination was found on the lid of the pre-filter housing in the Sodium Removal Ion Exchange System during routine filter change. Subsequent investigation determined that the alpha contamination likely came from a fuel pin(s) contained in an Ident-69 (ID-69) type pin storage container serial number 9 (ID-69-9) that was washed in the Sodium Removal System (SRS) in January 2004. Because all evidence indicated that the wash water interacted with the fuel, this ID-69 is designated as containing a failed fuel pin with gross cladding defect and was set aside in the Interim Examination and Maintenance (IEM) Cell until it could be determined how to proceed for long term dry storage of the fuel pin container. This ID-69 contained fuel pins from the driver fuel assembly (DFA) 16392, which was identified as a Delayed Neutron Monitor (DNM) leaker assembly. However, this DFA was disassembled and the fuel pin that was thought to be the failed pin was encapsulated and was not located in this ID-69 container.