Self-Calibrating Remote Control Chemical Monitoring System.
Croft, J.
Technical Information Center Oak Ridge Tennessee
关键词: Water pollution monitoring;    Remote monitoring;    Mine waste water;    Data collection;    Design;   
RP-ID  :  DE2007912463
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The Susie Mine, part of the Upper Tenmile Mining Area, is located in Rimini, MT about 15 miles southwest of Helena, MT. The Upper Tenmile Creek Mining Area is an EPA Superfund site with 70 abandoned hard rock mines and several residential yards prioritized for clean up. Water from the Susie mine flows into Tenmile Creek from which the city of Helena draws part of its water supply. MSE Technology Applications in Butte, Montana was contracted by the EPA to build a treatment system for the Susie mine effluent and demonstrate a system capable of treating mine waste water in remote locations. The Idaho National Lab was contracted to design, build and demonstrate a low maintenance self-calibrating monitoring system that would monitor multiple sample points, allow remote two-way communications with the control software and allow access to the collected data through a web site. The Automated Chemical Analysis Monitoring (ACAM) system was installed in December 2006. This thesis documents the overall design of the hardware, control software and website, the data collected while MSE-TAs system was operational, the data collected after MSE-TAs system was shut down and suggested improvements to the existing system.

【 预 览 】
附件列表
Files Size Format View
DE2007912463.pdf 1771KB PDF download
  文献评价指标  