科技报告详细信息
Corrosion Behavior of 304 Stainless Steel in High Temperature, Hydrogenated Water.
Ziemniak, S. E. ; Hanson, M.
Technical Information Center Oak Ridge Tennessee
关键词: Corrosion;    Stainless steels;    High temperatures;    Hydrogen;    Argon ions;   
RP-ID  :  DE2004821681
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The corrosion behavior of an austenitic stainless steel (UNS S30400) has been characterized in a 10,000 hour test conducted in hydrogenated, ammoniated water at 260 degrees C. The corrosion kinetics were observed to follow a parabolic rate dependency, the parabolic rate constant being determined by chemical descaling to be 1.16 mg dm(sup -2) hr(sup -1/2). X-ray photoelectron spectroscopy, in combination with argon ion milling and target factor analysis, was applied to provide an independent estimate of the rate constant that agreed with the gravimetric result.

【 预 览 】
附件列表
Files Size Format View
DE2004821681.pdf 1173KB PDF download
  文献评价指标  
  下载次数:5次 浏览次数:17次