科技报告详细信息
Ultrasonic Examination of Double-Shell Tank 241-AP-106 Examination Completed November 2004.
Pardini, A. F. ; Posakony, G. J.
Technical Information Center Oak Ridge Tennessee
关键词: Tanks(Containers);    Ultrasonic tests;    Radioactive waste storage;    Nondestructive tests;    Hanford Reservation;   
RP-ID  :  DE2005860096
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

COGEMA Engineering Corporation (COGEMA), under a contract from CH2M Hill Hanford Group (CH2M Hill), has performed an ultrasonic nondestructive examination of selected portions of Double-Shell Tank 241-AP-106. The purpose of this examination was to provide information that could be used to evaluate the integrity of the wall of the primary tank. The requirements for the ultrasonic examination of Tank 241-AP-106 were to detect, characterize (identify, size, and locate), and record measurements made of any wall thinning, pitting, or cracks that might be present in the wall of the primary tank. Any measurements that exceed the requirements set forth in the Engineering Task Plan (ETP), RPP-22571 (Jensen 2004) and summarized on page 1 of this document, are reported to CH2M Hill and the Pacific Northwest National Laboratory (PNNL) for further evaluation. Under the contract with CH2M Hill, all data is to be recorded on disk and paper copies of all measurements are provided to PNNL for third-party evaluation. PNNL is responsible for preparing a report that describes the results of the COGEMA ultrasonic examinations.

【 预 览 】
附件列表
Files Size Format View
DE2005860096.pdf 954KB PDF download
  文献评价指标  