科技报告详细信息
Evaluation of maxim Module-Integrated Electronics at the DOE Regional Test Center, 40th IEEE PVSC, Denver, CO.
Deline, C. ; Sekulic, B. ; Barkaszi, S. ; Yang, J. ; Kahn, S.
Technical Information Center Oak Ridge Tennessee
关键词: Electronic equipment;    Computerized simulation;    Irradiance;    Laboratory tests;    Losses;   
RP-ID  :  DE141136207
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

Module-embedded power electronics developed by Maxim Integrated are under evaluation through a partnership with the Department of Energy's Regional Test Center (RTC) program. Field deployments of both conventional modules and electronics-enhanced modules are designed to quantify the performance advantage of Maxim's products under different amounts of interrow shading, and their ability to be deployed at a greater ground-coverage ratio than conventional modules. Simulations in PVSYST have quantified the predicted performance difference between conventional modules and Maxim's modules from interrow shading. Initial performance results have identified diffuse irradiance losses at tighter row spacing for both the Maxim and conventional modules. Comparisons with published models show good agreement with models predicting the greatest diffuse irradiance losses. At tighter row spacing, all of the strings equipped with embedded power electronics outperformed their conventional peers. An even greater performance advantage is predicted to occur in the winter months when the amount of interrow shading mismatch is at a maximum.

【 预 览 】
附件列表
Files Size Format View
DE141136207.pdf 708KB PDF download
  文献评价指标  
  下载次数:46次 浏览次数:34次