科技报告详细信息
Analytical Results for MOX Colemanite Concrete Samples Received on January 15, 2013. (Revision 1).
Reigel, M.
Technical Information Center Oak Ridge Tennessee
关键词: Mixed oxide fuels;    Concretes;    Bearings;    Borons;    Criticality;   
RP-ID  :  DE141132255
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received twelve samples of colemanite concrete for analysis on January 15, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented in the following table. For all the samples tested, the total density and the hydrogen partial density met or exceeded the specified limit. All of the samples met or exceeded the boron partial density lower bound with the exception of samples G3-M11-2000-H, G3-M11-3000-M, and G5-M1-3000-H which are below the limit of 1.65E-01 g/cm3.

【 预 览 】
附件列表
Files Size Format View
DE141132255.pdf 652KB PDF download
  文献评价指标  
  下载次数:20次 浏览次数:12次