科技报告详细信息
Indoor Carbon Dioxide Concentrations, VOCS, Environmental Sensitivity Association with Mucous Membrane and Lower Respiratory Sick Building Syndrome Symptoms in the Base Study: Analyses of the 100 Building Dataset.
Apte, M. G. ; Erdmann, C. A.
Technical Information Center Oak Ridge Tennessee
关键词: Office buildings;    Indoor air pollution;    Carbon dioxide;    Mucous membranes;    Respiratory system;   
RP-ID  :  DE2003806126
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

Using the 100 office-building Building Assessment Survey and Evaluation (BASE) Study dataset, we performed multivariate logistic regression analyses to quantify the associations between indoor minus outdoor CO(sub 2) (dCO(sub 2)) concentrations and mucous membrane (MM) and lower respiratory system (Lresp) Sick Building Syndrome (SBS) symptoms, adjusting for age, sex, smoking status, presence of carpet in workspace, thermal exposure, relative humidity, and a marker for entrained automobile exhaust. Using principal components analysis we identified a number of possible sources of 73 measured volatile organic compounds in the office buildings, and assessed the impact of these VOCs on the probability of presenting the SBS symptoms. Additionally we included analysis adjusting for the risks for predisposition of having SBS symptoms associated with the allergic, asthmatic, and environmentally sensitive subpopulations within the office buildings.

【 预 览 】
附件列表
Files Size Format View
DE2003806126.pdf 645KB PDF download