科技报告详细信息
Effect of Sink Temperature on a Capillary Pumped Loop Employing a Flat Evaporator and Shell and Tube Condenser.
Cerza, M. ; Herron, R. C. ; Harper, J. J.
Technical Information Center Oak Ridge Tennessee
关键词: Temperature;    Heat sinks;    Heat transfer;    Heat flux;    Evaporators;   
RP-ID  :  DE2004821698
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

An experimental facility for conducting research on capillary pumped loop (CPL) systems was developed. In order to simulate shipboard cooling water encountered at various locations of the ocean, the heat sink temperature of the facility could be varied. A flat plate, CPL evaporator was designed and tested under various heat sink temperatures. The sink temperature ranged from 274.3 to 305.2 K and the heat input varied from 250 to 800 W which corresponds to heat fluxes up to 1.8 W/cm(sup 2). The CPL flat plate evaporator performed very well under this range of heat input and sink temperatures. The main result obtained showed that a large degree of subcooling developed between the evaporator vapor outlet line and liquid return line. This condensate depression increased with increasing heat input.

【 预 览 】
附件列表
Files Size Format View
DE2004821698.pdf 615KB PDF download
  文献评价指标  
  下载次数:13次 浏览次数:11次