科技报告详细信息
Operational Aspects of the Main Injector Large Aperture Quadrupole (WQB). | |
Chou, W. ; Bartelson, L. ; Brown, B. ; Capista, D. ; Crisp, J. | |
Technical Information Center Oak Ridge Tennessee | |
关键词: Fermilab; Injectors; Operation; Beam loss; WQB(Large Aperture Quadrupole); | |
RP-ID : DE2007914590 | |
学科分类:工程和技术(综合) | |
美国|英语 | |
来源: National Technical Reports Library | |
【 摘 要 】
A two-year Large Aperture Quadrupole (WQB) Project was completed in the summer of 2006 at Fermilab. Nine WQBs were designed, fabricated and bench-tested by the Technical Division. Seven of them were installed in the Main Injector and the other two for spares. They perform well. The aperture increase meets the design goal and the perturbation to the lattice is minimal. The machine acceptance in the injection and extraction regions is increased from 40 to 60 mm-mrad. This paper gives a brief report of the operation and performance of these magnets.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
DE2007914590.pdf | 563KB | download |