Double-Shell Tanks Chemistry Control Data Quality Objectives.
Banning, D. L.
Technical Information Center Oak Ridge Tennessee
关键词: Hanford Reservation;    Tanks;    Chemistry controls;    Corrosion;    Data base management;   
RP-ID  :  DE2003807269
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

One of the main functions of the River Protection Project is to store the Hanford Site tank waste until the Waste Treatment Plant (WTP) is ready to receive and process the waste. Waste from the older single-shell tanks is being transferred to the newer double-shell tanks (DSTs). Therefore, the integrity of the DSTs must be maintained until the waste from all tanks has been retrieved and transferred to the WTP. To help maintain the integrity of the DSTs over the life of the project, specific chemistry limits have been established to control corrosion of the DSTs. These waste chemistry limits are presented in the Technical Safety Requirements (TSR) document HNF-SD-WM-TSR-006, Sec. 5.15, Rev 2 5 (CHG 2001). In order to control the chemistry in the DSTs, the Chemistry Control Program will require analyses of the tank waste.