Dimensional Measurements of Three Tubes by Computed Tomography.
Schneberk, D. J. ; Martz, H. E. ; Brown, W. D.
Technical Information Center Oak Ridge Tennessee
关键词: Computer aided tomography;    Tomography;    Tubes;    Polyethylenes;    Three dimensional model;   
RP-ID  :  DE200515014597
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

Low density polyethylene (LDPE), copper (Cu), and gold (Au) tubes were scanned on KCAT to identify and evaluate the impact of phase effects on quantitative object recovery. These tubes are phantoms for high energy density capsules. Digital radiographs for each tube are shown in Figure 1. The LDPE tube was scanned at 60 kV, while the Cu and the Au tubes were scanned at 140 kV. All tubes were scanned at a magnification of 3, with approximately 100-mm distance between the exit plane of the tube and the scintillator. Notice the prominence of the outer bright and inner dark edges for the LDPE tube DR, and their absence from the Cu and Au tube DRs. The bright and dark edges are a result of change in phase of the x-rays. The x-ray fluence is partly attenuated and partly refracted. The location near the outer edge of the tube appears to be more attenuating since those x-rays have refracted to locations just outside the tube. Alternatively, the added counts from the refraction result in intensities that are greater than the incident intensity effectively representing a negative attenuation. This results in more counts in that location than in the incident intensity image violating the positivedefinite requirement for standard CT reconstruction methodologies. One aspect of our CT processing techniques remove some of this signal on the outside of the object. The goal of this paper is to evaluate the accuracy of our dimensional measurement methods for mesoscale object inspection.

【 预 览 】
附件列表
Files Size Format View
DE200515014597.pdf 421KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:28次