The Materials Identification and Surveillance (MIS) program was established within the 94-1 R&D Program to confirm the suitability of plutonium-bearing materials for stabilization, packaging, and long-term storage under DOE-STD-3013-2000. Oxide materials from different sites were chemically and physically characterized. The adequacy of the stabilization process parameters of temperature and duration at temperature for eliminating chemical reactivity and reducing the moisture content to less than 0.5 weight percent were validated. Studies also include surveillance monitoring to determine the behavior of the oxides and packaging materials under storage conditions. Materials selected for this program were assumed to be representative of the overall inventory for DOE sites. The Quality Assurance section of the DOE-STD-3013-2000 required that each site be responsible for assuring that oxides packaged according to this standard are represented by items in the MIS characterization program. The purpose of this document is to define the path for determining if an individual item is represented in the MIS Program and to show that oxides being packaged at Lawrence Livermore National Laboratory (LLNL) are considered represented in the MIS program.