Acceptance Test Plan for Fourth Generation Hanford Corrosion Monitoring System.
Norman, E. C.
Technical Information Center Oak Ridge Tennessee
关键词: Radioactive waste storage;    Corrosion;    Monitoring;    Tanks;    Radioactive wastes;   
RP-ID  :  DE2003804244
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The objective of this procedure is to demonstrate and document the acceptance of the corrosion monitoring cabinets to be installed on tanks 241-AN-IO2 and 241-AN-107. One cabinet will be installed on each tank. Each cabinet will contain corrosion monitoring hardware to be connected to existing corrosion probes already installed in each tank. The test will consist of a continuity test of the cabinet wiring from the end of cable to be connected to corrosion probe, through the appropriate intrinsic safety barriers and out to the 15 pin D-shell connectors to be connected to the corrosion monitoring instrument. Additional testing will be performed using a constant current and voltage source provided by the corrosion monitoring hardware manufacturer to verify proper operation of corrosion monitoring instrumentation (input a known signal and see if the instrumentation records the proper value).

【 预 览 】
附件列表
Files Size Format View
DE2003804244.pdf 295KB PDF download