It was recently discovered that waste being disposed of onsite contained radionuclides that had not been analyzed by the Performance Assessment (PA). These radionuclides had been eliminated from the PA in an earlier screening evaluation because they were not expected to be contained in SRS-generated waste or that received from offsite generators. This Special Analysis (SA) is being prepared to establish the screening criteria and level of evaluation for all radionuclides potentially significant to a Low Level Waste PA or Composite Analysis (CA). The screening methodology recommended by the National Council on Radiological Protection and Measurements (NCRP) has been used to identify those radionuclides that require detailed analysis to derive disposal limits.