科技报告详细信息
Axial Pressure Drop Measurements during Pilot-Scale Testing of a Mott Crossflow Filter.
Poirier, M. R. ; Fink, S. D. ; Haggard, R. ; Deal, T.
Technical Information Center Oak Ridge Tennessee
关键词: Filtration;    Pressure drop;    High level radioactive wastes;    Filters;    Supernates;   
RP-ID  :  DE2004833807
学科分类:工程和技术(综合)
美国|英语
来源: National Technical Reports Library
PDF
【 摘 要 】

The Department of Energy selected CSSX as the preferred cesium removal technology for Savannah River Site waste. As a pretreatment step for the CSSX flowsheet, personnel contact the incoming salt solution that contains entrained sludge with MST to adsorb strontium and select actinides. They filter the resulting slurry to remove the sludge and MST. The filtrate receives further treatment to remove cesium in the solvent extraction system. The baseline filtration technology uses a Mott crossflow filter. We conducted pilot-scale crossflow filter testing with simulated SRS high level waste to evaluate the impact of operating parameters on the crossflow filtration process. The tests employed 0.5 micron and 0.1 micron filters. The feed slurries for these tests included simulated sludge plus MST, simulated sludge only, and simulated sludge plus manganese oxide solids. The supernate for these tests consisted of 5.6-6.4 M sodium, average salt solution. During the tests, we measured the axial pressure drop as a function of axial velocity, feed slurry, and insoluble solids concentration. This report documents the axial pressure drop data.

【 预 览 】
附件列表
Files Size Format View
DE2004833807.pdf 279KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:17次