科技报告详细信息
Thermal Design and Analysis of Cooling SOFIA HIRMES to 4K Cryogenic Temperature Using Cryocooler
Choi, Michael K
关键词: THERMAL ANALYSIS;    DESIGN ANALYSIS;    PULSE TUBE CRYOCOOLERS (PTC);    CRYOGENIC COOLING;    SOFIA (AIRBORNE OBSERVATORY);    CRYOGENIC TEMPERATURE;    HEAT TRANSMISSION;    THERMAL CONDUCTIVITY;    SPECTROSCOPIC TELESCOPES;    INFRARED SPECTROMETERS;    INFRARED ASTRONOMY;   
RP-ID  :  ICES-2019-276,GSFC-E-DAA-TN68767
美国|英语
来源: NASA Technical Reports Server
PDF
【 摘 要 】
HIgh Resolution Mid-infrarEd Spectrometer (HIRMES) is a facility-class instrument aboard the Stratospheric Observatory for Infrared Astronomy (SOFIA) Aircraft Observatory. A TransMIT PTD 406C pulse tube cryocooler (PTC) is used to cool the optical bench and optical components to 4K. A second PTC is dedicated to cool the 3He/4He sorption cooler. The first stages of the PTCs share the heat load from the intermediate temperature stage. The second stage of the first PTC removes nearly all the heat load from the 4 degrees Kelvin stage. The results of thermal analysis show that the 4 degrees Kelvin stage of the HIRMES thermal subsystem meets all of its requirements using the 100 percent heat load margin approach and conservative modeling assumptions.
【 预 览 】
附件列表
Files Size Format View
20190027099.pdf 1906KB PDF download
  文献评价指标  
  下载次数:3次 浏览次数:24次