科技报告详细信息
Toughness Testing for Liquid Hydrogen And Helium Temperatures - Validation of Austenitic Stainless Steels for 4K (-452F) Use
Greulich, Owen R ; Lambert, Dennis M ; Tang, Xiaoli (Shelly) ; Sahici, Selin
关键词: AUSTENITIC STAINLESS STEELS;    FRACTURE STRENGTH;    LEAKAGE;    LIQUID HELIUM;    LIQUID HYDROGEN;    STANDARD DEVIATION;    TOUGHNESS;    CHARPY IMPACT TEST;    CHEMICAL COMPOSITION;    COMPRESSIVE STRENGTH;    HARDNESS;    PRESSURE VESSELS;   
RP-ID  :  HQ-E-DAA-TN60692
美国|英语
来源: NASA Technical Reports Server
PDF
【 摘 要 】

This presentation is an Existing Code Requirement: Charpy impact test at a temperature no higher than the design minimum temperature. The Current Practice: is not clear, the indications are that testing is sometimes performed at -320F (liquid nitrogen or "LN2") for that and all lower temperatures. In some cases testing is probably not performed and CGA indicated successful operation of systems at -453F without required test. The Ballot activity: C&S Connect Record 13-341, Ballot 13-1746, initially proposed Charpy testing (lateral expansion criteria) at -320F to validate use at -425 (liquid helium or "LHe"). and PTCS Proposal..

【 预 览 】
附件列表
Files Size Format View
20180006710.pdf 1050KB PDF download