科技报告详细信息
Use of the Ames Check Standard Model for the Validation of Wall Interference Corrections
Ulbrich, N ; Amaya, M ; Flach, R
关键词: WALL FLOW;    AERODYNAMIC INTERFERENCE;    AERODYNAMIC COEFFICIENTS;    CORRECTION;    DYNAMIC PRESSURE;    TRANSONIC WIND TUNNELS;    TEST CHAMBERS;    SLOTS;    ANGLE OF ATTACK;    ROTATION;    FLOORS;   
RP-ID  :  ARC-E-DAA-TN48993
学科分类:航空航天科学
美国|英语
来源: NASA Technical Reports Server
PDF
【 摘 要 】

The new check standard model of the NASA Ames 11-ft Transonic Wind Tunnel was chosen for a future validation of the facility's wall interference correction system. The chosen validation approach takes advantage of the fact that test conditions experienced by a large model in the slotted part of the tunnel's test section will change significantly if a subset of the slots is temporarily sealed. Therefore, the model's aerodynamic coefficients have to be recorded, corrected, and compared for two different test section configurations in order to perform the validation. Test section configurations with highly accurate Mach number and dynamic pressure calibrations were selected for the validation. First, the model is tested with all test section slots in open configuration while keeping the model's center of rotation on the tunnel centerline. In the next step, slots on the test section floor are sealed and the model is moved to a new center of rotation that is 33 inches below the tunnel centerline. Then, the original angle of attack sweeps are repeated. Afterwards, wall interference corrections are applied to both test data sets and response surface models of the resulting aerodynamic coefficients in interference-free flow are generated. Finally, the response surface models are used to predict the aerodynamic coefficients for a family of angles of attack while keeping dynamic pressure, Mach number, and Reynolds number constant. The validation is considered successful if the corrected aerodynamic coefficients obtained from the related response surface model pair show good agreement. Residual differences between the corrected coefficient sets will be analyzed as well because they are an indicator of the overall accuracy of the facility's wall interference correction process.

【 预 览 】
附件列表
Files Size Format View
20180000582.pdf 3536KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:16次