科技报告详细信息
LCLS Undulator Test Plan | |
Wolf, Zachary | |
SLAC National Accelerator Laboratory | |
关键词: Storage; Tuning; Xfel; 43 Particle Accelerators; Stanford Linear Accelerator Center; | |
DOI : 10.2172/993407 RP-ID : SLAC-TN-10-055 RP-ID : AC02-76SF00515 RP-ID : 993407 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
This note presents the test plan for the LCLS undulators. The undulators will be measured and tuned in the Magnetic Measurement Facility at SLAC. The requirements for tuning are well established and are summarized. A brief discussion of the measurement equipment is presented. This is followed by the detailed test plan in which each step is enumerated. Finally, the measurement results and storage format are presented. The LCLS consists of 33 undulator segments, hereafter referred to as undulators, plus 6 spares and one reference undulator. The undulators must be tuned to meet strict requirements. They must also be fiducialized to allow alignment with other components. This note details the plan for tuning and fiducializing the LCLS undulators. The note begins with the list of tuning and fiducialization requirements. The laboratory in which the work will be performed and the relevant equipment is then briefly described. This is followed by a detailed test plan in which all the steps of tuning and fiducialization are enumerated.【 预 览 】
Files | Size | Format | View |
---|---|---|---|
993407.pdf | 173KB | download |