SXR Continuum Radiation Transmitted Through Metallic Filters: An Analytical Approach To Fast Electron Temperature Measurements | |
Delgado-Aparicio, L. ; Tritz, K. ; Kramer, T. ; Stutman, D. ; Finkentha, M. ; Hill, K. ; Bitter, M. | |
Princeton University. Plasma Physics Laboratory. | |
关键词: Plasma X-Ray, Srx; X-Ray, Srx; 70 Plasma Physics And Fusion Technology; Thermonuclear Devices; Soft X Radiation; | |
DOI : 10.2172/988882 RP-ID : PPPL-4543 RP-ID : DE-ACO2-09CH11466 RP-ID : 988882 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
A new set of analytic formulae describes the transmission of soft X-ray (SXR) continuum radiation through a metallic foil for its application to fast electron temperature measurements in fusion plasmas. This novel approach shows good agreement with numerical calculations over a wide range of plasma temperatures in contrast with the solutions obtained when using a transmission approximated by a single-Heaviside function [S. von Goeler, Rev. Sci. Instrum., 20, 599, (1999)]. The new analytic formulae can improve the interpretation of the experimental results and thus contribute in obtaining fast teperature measurements in between intermittent Thomson Scattering data.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
988882.pdf | 630KB | download |