科技报告详细信息
Design Parameters and Objectives of a High-­Resolution X-­ray Imaging Crystal Spectrometer for the Large Helical Device (LHD)
Bitter, M. ; Gates, D. ; Neilson, H. ; Reiman, A. ; Roquemore, A. L. ; Morita, S. ; Goto, M. ; Yamada, H.
Princeton University. Plasma Physics Laboratory.
关键词: Heating;    Spectra;    Magnetic Fields;    70 Plasma Physics And Fusion Technology;    Spectrometers;   
DOI  :  10.2172/981706
RP-ID  :  PPPL-4514
RP-ID  :  DE-ACO2-09CH11466
RP-ID  :  981706
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

A high-resolution X-ray imaging crystal spectrometer, whose instrumental concept was thoroughly tested on NSTX and Alcator C-Mod, is presently being designed for LHD. The instrument will record spatially resolved spectra of helium-like Ar16+ and provide ion temperature profiles with spatial and temporal resolutions of 1 cm and > 10 ms which are obtained by a tomographic inversion of the spectral data, using the stellarator equilibrium reconstruction codes, STELLOPT and PIES. Since the spectrometer will be equipped with radiation hardened, high count rate, PILATUS detectors,, it is expected to be operational for all experimental conditions on LHD, which include plasmas of high density and plasmas with auxiliary RF and neutral beam heating. The special design features required by the magnetic field structure at LHD will be described.

【 预 览 】
附件列表
Files Size Format View
981706.pdf 5668KB PDF download
  文献评价指标  