科技报告详细信息
REPORT ON ELECTROCHEMICAL CORROSION TESTING FOR TANK 241-AN-106 USING 2009 SAMPLING CAMPAIGN GRAB SAMPLES
RB, WYRWAS
Hanford Site (HNF), Richland, WA (United States)
关键词: Safety Engineering;    Radioactive Waste Storage;    Specifications;    Radioactive Wastes;    Electrochemical Corrosion;   
DOI  :  10.2172/981412
RP-ID  :  LAB-RPT-10-00007 Rev 0
RP-ID  :  DE-AC27-08RV14800
RP-ID  :  981412
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Based on an ENRAF waste surface measurement taken February 1, 2009, double-shell tank (DST) 24l-AN-l06 (AN-106) contained approximately 278.98 inches (793 kgal) of waste. A zip cord measurement from the tank on February 1, 2009, indicated a settled solids layer of 9l.7 inches in height (280 kgal). The supernatant layer in February 2009, by difference, was approximately 187 inches deep (514 kgal). Laboratory results from AN-l06 February 1, 2009 (see Table 2) grab samples indicated the supernatant was below the chemistry limit that applied at the time as identified in HNF-SD-WM-TSR-006, 'Tank Farms Technical Safety Requirements', Administrative Control (AC) 5.16, 'Corrosion Mitigation Controls.' The limits have since been removed from the Technical Safety Requirements (TSR) and are captured in OSD-T-15l-00007, 'Operating Specifications for the Double-Shell Storage Tanks.' Problem evaluation request WRPS-PER-2009-0218 was submitted February 9,2009, to document the finding that the supernatant chemistry for grab samples taken from the middle and upper regions of the supernatant was noncompliant with the chemistry control limits. The lab results for the samples taken from the bottom region of the supernatant met AC 5.16 limits.

【 预 览 】
附件列表
Files Size Format View
981412.pdf 16844KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:27次