科技报告详细信息
STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE
JE, MEACHAM
Hanford Site (Wash.)
关键词: Flammability;    Radioactive Wastes;    Storage Facilities;    Degassing;    Ventilation;   
DOI  :  10.2172/967370
RP-ID  :  RPP-5926 Rev 8
RP-ID  :  DE-AC27-08RV14800
RP-ID  :  967370
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
This report assesses the steady state flammability level under off normal ventilation conditions in the tank headspace for 28 double-shell tanks (DST) and 149 single shell-tanks (SST) at the Hanford Site. Flammability was calculated using estimated gas release rates, Le Chatelier's rule, and lower flammability limits of fuels in an air mixture. This revision updates the hydrogen generation rate input data for al1 177 tanks using waste composition information from the Best Basis Inventory Detail Report (data effective as of August 4,2008). Assuming only barometric breathing, the shortest time to reach 25% of the lower flammability limit is 13 days for DSTs (i.e., tank 241-AZ-102) and 36 days for SSTs (i.e., tank 241-B-203). Assuming zero ventilation, the shortest time to reach 25% of the lower flammability limit is 12 days for DSTs (i.e., tank 241-AZ-102) and 34 days for SSTs (i.e., tank 241-B-203).
【 预 览 】
附件列表
Files Size Format View
967370.pdf 5864KB PDF download
  文献评价指标  
  下载次数:30次 浏览次数:90次