科技报告详细信息
STEADY STATE FLAMMABLE GAS RELEASE RATE CALCULATION AND LOWER FLAMMABILITY LEVEL EVALUATION FOR HANFORD TANK WASTE
TA, HU
Hanford Site (Wash.)
关键词: 08 Hydrogen;    Flammability;    Wastes;    Hydrogen;    Methane;   
DOI  :  10.2172/967368
RP-ID  :  RPP-5926 Rev 6
RP-ID  :  DE-AC27-99RL14047
RP-ID  :  967368
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Assess the steady-state flammability level at normal and off-normal ventilation conditions. The hydrogen generation rate was calculated for 177 tanks using the rate equation model. Flammability calculations based on hydrogen, ammonia, and methane were performed for 177 tanks for various scenarios.

【 预 览 】
附件列表
Files Size Format View
967368.pdf 10774KB PDF download