科技报告详细信息
Area Monitoring Dosimeter Program for the Pacific Northwest National Laboratory: Results for CY 1999
Bivins, Steven R. ; Stoetzel, Gregory A.
Pacific Northwest National Laboratory (U.S.)
关键词: Thermoluminescent Dosimetry Personnel Dosimetry;    Battelle Pacific Northwest Laboratories;    Mrem;    Program Management;    1999;   
DOI  :  10.2172/965188
RP-ID  :  PNNL-13322
RP-ID  :  AC05-76RL01830
RP-ID  :  965188
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

In January 1993, PNNL established an area monitoring dosimeter program in accordance with Article 514 of the DOE Radiological Control Manual. This program was to minimize the number of areas requiring issuance of personnel dosimeters and to demonstrate that doses outside Radiological Buffer Areas are negligible. In accordance with 10 CFR Part 835.402 (a)(1)-(4) and Article 511.1 of the DOE Standard Radiological Control, personnel dosimetry shall be provided to 1) radiological workers who are likely to receive at least 100 mrem annually and 2) declared pregnant workers, minors, and members of the public who are likely to receive at least 50 mrem annually. Program results for calendar years 1993-1998 confirmed that personnel dosimetry was not needed for individuals located in areas monitored by the program. A total of 123 area thermoluminescent dosimeters (TLDs) were placed in PNNL facilities during calendar year 1999. The TLDs were exchanged and analyzed quarterly. All routine area monitoring TLD results were less than 50 mrem annually after correcting for worker occupancy. The results support the conclusion that personnel dosimeters are not necessary for staff, declared pregnant workers, minors, or members of the public in these monitored areas.

【 预 览 】
附件列表
Files Size Format View
965188.pdf 1325KB PDF download
  文献评价指标  
  下载次数:33次 浏览次数:38次