Remaining Sites Verification Package for the 116-F-8, 1904-F Outfall Structure and the 100-F-42, 1904-F Spillway, Waste Site Reclassification Form 2006-038
Dittmer, L. M.
Washington Closure Hanford
关键词: 1904-F Outfall Structure;    Columbia River;    100F Area;    12 Management Of Radioactive And Non-Radioactive Wastes From Nuclear Facilities;    Hanford;   
DOI  :  10.2172/944423
RP-ID  :  RSVP-2006-038
RP-ID  :  DE-AC06-05RL14655
RP-ID  :  944423
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The 116-F-8 waste site is the former 1904-F Outfall Structure used to discharge reactor cooling water effluent fro mthe 107-F Retention Basin to the Columbia River. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

【 预 览 】
附件列表
Files Size Format View
944423.pdf 8318KB PDF download