ELECTROCHEMICAL CORROSION TESTS FOR TANK 241-AY-101 CORE 325 SEGMENTS 16R1 & 16R2 | |
JB, DUNCAN ; RB, WYRWAS | |
Hanford Site (Wash.) | |
关键词: Corrosion; Carbon Steels; Hydroxides; Storage Facilities; Specifications; | |
DOI : 10.2172/940019 RP-ID : RPP-RPT-35554 Rev 1 RP-ID : DE-AC27-99RL14047 RP-ID : 940019 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The interstitial liquid in the double-shell tank 241-AY-101 settled solids layer is below the hydroxide chemistry control limit required by HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control 5.16, 'Corrosion Mitigation Controls'. Operating tanks outside of the specification may increase the propensity corrosion of the carbon steel wall. This report is concerned with generalized electrochemical corrosion mechanism that may occur at specific loci. All cyclic potentiodynamic polarization scans exhibited a negative hysteresis, scan reversing at lower current density, indicating that there was no pitting propensity. The general electrochemical corrosion rates ranged from 4.4E-02 to 1.5E-03 mpy with the first round of coupons, while the second round yielded corrosion rates of 2.5E-03 to 2.9E-02 mpy.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
940019.pdf | 3604KB | download |