ORNL/IAT ARMATURE DIAGNOSTICS DEMONSTRATION TEST REPORT: PART TWO: BENCH DEMONSTRATION | |
Allison, Stephen W ; Cates, Michael R ; Goedeke, Shawn ; Crawford, M. T. ; Ferraro, S. B. ; Surls, D. ; Stewart, J. | |
Oak Ridge National Laboratory | |
关键词: Fluorescence; Armatures; Performance Testing; 42 Engineering; Diagnostic Techniques; | |
DOI : 10.2172/930854 RP-ID : ORNL/TM-2006/594 RP-ID : DE-AC05-00OR22725 RP-ID : 930854 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
The purpose of the present effort was to demonstrate 'on the fly' temperature measurement of railgun armatures on a bench top railgun. The effort builds on the previous test that utilized a portable unit with armature speeds ranging from 50 to 90 m/s. The tests described here involved higher speeds, ranging from 300 to 500 m/s. The method to accomplish the measurement involves pulsed laser illumination of a phosphor-coated armature. The duration of the ensuing fluorescence indicates temperature. The measured temperatures, obtained both inside the muzzle and outside in free flight, ranged between 80 to 110 C. The required pulsed fluorescence was made possible by successfully sensing the position of the armature while traveling within the laser illumination and fluorescence sensing fields-of-view. A high-speed camera also captured images of the moving armatures after exiting the railgun. These images sometimes included the fluorescing region of the phosphor coating.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
930854.pdf | 897KB | download |