FILL STEM MANUFACTURING CHANGES AND PINCH WELD QUALIFICATIONS | |
Korinko, P ; David Maxwell, D | |
Savannah River Site (S.C.) | |
关键词: Chemical Composition; Welded Joints; 36 Materials Science; Performance Testing; Welding; | |
DOI : 10.2172/927165 RP-ID : WSRC-STI-2008-00098 RP-ID : DE-AC09-96SR18500 RP-ID : 927165 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
In March of 2007 a document was issued, see attachment I, that defined the test protocol and required welding for the Kansas City Plant to change cutting oils from the recently approved 50:50 oil to an oil with similar characteristics but with different chemistry, additives, and possibly a different vendor due to plans by the current vendor to stop preparing the oils that are used in the KCP 50:50 mix. The KCP manufactured stems with the existing 50:50 oil blend in late FY07 and SRNL welded the stems and evaluated them in agreement with the test plan. This report provides all the data from these set-up and test welds. Set-up welds were shot and low and high voltages (currents) to ensure the window limits were applicable and then additional welds were made to validate the window. The purpose of this report is to ensure that the agreed upon path forward is still applicable.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
927165.pdf | 4410KB | download |