科技报告详细信息
Using the quadrupole moment frequency response of bunched beam to measure its transverse emittance
Tan, Cheng-Yang
Fermi National Accelerator Laboratory
关键词: Quadrupole Moments;    43 Particle Accelerators;    Synchrotrons Accelerators;    Quadrupoles;    Accelerators;   
DOI  :  10.2172/919077
RP-ID  :  FERMILAB-TM-2397-AD
RP-ID  :  AC02-07CH11359
RP-ID  :  919077
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The quadrupole moment measured with a quadrupole pickup has been used to measure the transverse emittance of the beam. Unfortunately, the poor S/N ratio in the measurement makes it difficult to produce good and consistent emittance results. One way to enhance the S/N is to kick the beam with a quadrupole kicker and then measure its quadrupole frequency response (QFR) with a quadrupole pickup. This paper will show that if the bunched beam is extremely short, the quadrupole tunes are well decoupled and far apart, and the quadrupole tune spread is smaller than the synchrotron tune, then the emittance can be extracted from the QFR.

【 预 览 】
附件列表
Files Size Format View
919077.pdf 2077KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:16次