| Borehole Gravity Meter Surveys at the Waste Treatment Plant, Hanford, Washington. | |
| MacQueen, Jeffrey D. ; Mann, Ethan | |
| Pacific Northwest National Laboratory (U.S.) | |
| 关键词: Radioactive Waste Facilities; Density; Boreholes; Geologic Models; 58 Geosciences; | |
| DOI : 10.2172/912733 RP-ID : PNNL-16490 RP-ID : AC05-76RL01830 RP-ID : 912733 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
Microg-LaCoste (MGL) was contracted by Pacfic Northwest National Laboratories (PNNL) to record borehole gravity density data in 3 wells at the HanfordWaste Treatment Plant (WTP) site. The survey was designed to provide highly accurate density information for use in seismic modeling. The borehole gravity meter (BHGM) tool has a very large depth of investigation (hundreds of feet) compared to other density tools so it is not influenced by casing or near welbore effects, such as washouts.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 912733.pdf | 3772KB |
PDF