科技报告详细信息
| Industrial Assessment Center (IAC) at Lehigh University | |
| Oztekin, Sudhakar Neti and Alparslan | |
| Lehigh University, Office of research and Sponsored Programs, 526 Brodhead Ave., Bethlehem, PA 18015 | |
| 关键词: 32 Energy Conservation, Consumption, And Utilization; Recommendations; Energy Efficiency, Energy Savings; Productivity; Energy Efficiency Energy Efficiency, Energy Savings; | |
| DOI : 10.2172/909603 RP-ID : FTR RP-ID : FC36-02GO12088 RP-ID : 909603 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
During the period September, 2001, through August, 2006, the Lehigh University Industrial Assessment Center provided assessments for 147 companies in the Eastern Pennsylvania and New Jersey. In reports sent to the companies, a total of 1,079 assessment recommendations were suggested, with an annual cost savings of $22,980,654, to save energy, reduce waste, and improve productivity. The energy saved if all ARs were implemented would be 1,843,202 MMBtu.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 909603.pdf | 19KB |
PDF