METHODOLOGY FOR THE NUMBER OF FILTERS NEEDED IN A WASTE BOX
MARUSICH, R.M.
Hanford Site (Wash.)
关键词: 08 Hydrogen;    Compliance;    Organic Compounds;    Wastes;    Volatile Matter;   
DOI  :  10.2172/907889
RP-ID  :  HNF-33512 Rev 0
RP-ID  :  DE-AC06-96RL13200
RP-ID  :  907889
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
Waste in large waste boxes can generate volatile organic compounds (VOCs) and hydrogen. These waste boxes may or may not have flow paths out of them (although it is believed that most do). These boxes will be retrieved, sampled, and then coated with polyurea. After coating, filters will be installed in the box to keep the concentration of VOCs and hydrogen acceptably low. The MDSA requires that a vent path must be protected during application of the polyurea coating. If the box has been sampled then it is vented and the vent path must be protected. This report provides a model in which the user inputs the free volume of the waste box, sample concentration (ppm of total VOC or volume fraction hydrogen) along with the number of filters to be placed into the waste box lid. Using this information, the model provides an estimate of concentration vs. time or the number of filters needed to reduce the concentration by a specified fraction. If the equations from this report are placed into spreadsheets which are then used to demonstrate TSR compliance, the spreadsheets must come under the Software QA Plan for such documents. Chapters 2 and 3 present the theory. Chapter 4 presents the method with examples of its use found in Chapter 5. Chapter 6 provides the basis far the use of 1,000 ppm as the concentration below which the method is valid under any condition.
【 预 览 】
附件列表
Files Size Format View
907889.pdf 3505KB PDF download
  文献评价指标  
  下载次数:0次 浏览次数:18次