科技报告详细信息
Plant-Wide Energy Efficiency Assessment at the Arizona Portland Cement Plant in Rillito, Arizona
Stephen J. Coppinger, P.E. ; Bruce Colburn, Ph.D., P.E., CEM
California Portland Cement Company
关键词: Energy Audits;    Arizona;    32 Energy Conservation, Consumption, And Utilization;    Energy Accounting;    Portland Cement;   
DOI  :  10.2172/903448
RP-ID  :  DOEGO15095
RP-ID  :  FG36-05GO15095
RP-ID  :  903448
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

A Department of Energy Plant-wide Assessment was undertaken by Arizona Portland Cement (APC) beginning in May 2005. The assessment was performed at APC’s cement production facility in Rillito, Arizona. The assessment included a compressed air evaluation along with a detailed process audit of plant operations and equipment. The purpose of this Energy Survey was to identify a series of energy cost savings opportunities at the Plant, and provide preliminary cost and savings estimates for the work. The assessment was successful in identifying projects that could provide annual savings of over $2.7 million at an estimated capital cost of $4.3 million. If implemented, these projects could amount to a savings of over 4.9 million kWh/yr and 384,420 MMBtu/year.

【 预 览 】
附件列表
Files Size Format View
903448.pdf 1232KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:18次