科技报告详细信息
Friction Factor Measurements in an Equally Spaced Triangular Tube Array
Vassallo P, Symolon P
Knolls Atomic Power Laboratory
关键词: Geometry;    Friction Factor;    Hydraulics;    42 Engineering;    Water;   
DOI  :  10.2172/903201
RP-ID  :  LM-07K012
RP-ID  :  DE-AC12-00SN39357
RP-ID  :  903201
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

Friction factor data for adiabatic cross-flow of water in a staggered tube array was obtained over a Reynolds number range (based on hydraulic diameter and gap velocity) of about 10,000 to 250,000. The tubes were 12.7mm (0.5 inch) outer diameter, in a uniformly spaced triangular arrangement with a pitch-to-diameter ratio of 1.5. The friction factor was compared to several literature correlations, and was found to be best matched by the Idelchik correlation. Other correlations were found to vary significantly from the test data. Based on the test data, a new correlation is proposed for this tube bundle geometry which covers the entire Reynolds number range tested.

【 预 览 】
附件列表
Files Size Format View
903201.pdf 266KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:10次