科技报告详细信息
Radiation calculations for the ILC cryomodule
Nakao, N. ; Mokhov, N.V. ; Klebaner, A. ; /Fermilab
Fermi National Accelerator Laboratory
关键词: Protons;    Photons;    Energy Spectra;    43 Particle Accelerators;    Radiations;   
DOI  :  10.2172/902540
RP-ID  :  FERMILAB-TM-2387-AD
RP-ID  :  AC02-07CH11359
RP-ID  :  902540
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】

The MARS15 radiation simulations were performed for the ILC cryomodule. The model assumes a uniform beam loss intensity of 1 W/m of 750-MeV and 250-GeV electron along the inner surface of the beam pipe and the cavity iris of the 12-m cryomodule. Two-dimensional distributions of radiation dose in the module were obtained. Absorbed dose rate and energy spectra of electrons, photons, neutrons and protons were also obtained at the three cryogenic thermometers locations by filling with silicon material in the appropriate locations, and radiation hardness of the thermometers was discussed. From the obtained results, maximum absorbed dose of thermometers at the cooling pipe is 0.85mGy/sec (85 mRad/sec), that is 0.31 MGy (31 MRad) for 20 years.