RCRA Assessment Plan for Single-Shell Tank Waste Management Area TX-TY | |
Horton, Duane G. | |
Pacific Northwest National Laboratory (U.S.) | |
关键词: Radioactive Waste Storage; Monitoring; Liquid Wastes; Storage Facilities; 11 Nuclear Fuel Cycle And Fuel Materials; | |
DOI : 10.2172/902398 RP-ID : PNNL-16005 RP-ID : AC05-76RL01830 RP-ID : 902398 |
|
美国|英语 | |
来源: UNT Digital Library | |
【 摘 要 】
WMA TX-TY contains underground, single-shell tanks that were used to store liquid waste that contained chemicals and radionuclides. Most of the liquid has been removed, and the remaining waste is regulated under the RCRA as modi¬fied in 40 CFR Part 265, Subpart F and Washington State’s Hazardous Waste Management Act . WMA TX-TY was placed in assessment monitoring in 1993 because of elevated specific conductance. A groundwater quality assessment plan was written in 1993 describing the monitoring activities to be used in deciding whether WMA TX-TY had affected groundwater. That plan was updated in 2001 for continued RCRA groundwater quality assessment as required by 40 CFR 265.93 (d)(7). This document further updates the assessment plan for WMA TX-TY by including (1) information obtained from ten new wells installed at the WMA after 1999 and (2) information from routine quarterly groundwater monitoring during the last five years. Also, this plan describes activities for continuing the groundwater assessment at WMA TX TY.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
902398.pdf | 4936KB | download |