科技报告详细信息
Pressure Model for the Vacuum System for the Electron Gun and Injector for LCLS Final Design Report
Tung, L S ; Eriksson, L
Lawrence Livermore National Laboratory
关键词: Light Sources;    43 Particle Accelerators;    42 Engineering;    Vacuum Systems;    Linear Accelerators;   
DOI  :  10.2172/889436
RP-ID  :  UCRL-TR-221253
RP-ID  :  W-7405-ENG-48
RP-ID  :  889436
美国|英语
来源: UNT Digital Library
PDF
【 摘 要 】
The vacuum system of the injector for the Linac Coherent Light Source (LCLS) has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The vacuum system layout and detailed analyses for the injector are presented in this final design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated.
【 预 览 】
附件列表
Files Size Format View
889436.pdf 2199KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:36次