科技报告详细信息
Pressure Model for the Vacuum System for the Electron Gun and Injector for LCLS Final Design Report | |
Tung, L S ; Eriksson, L | |
Lawrence Livermore National Laboratory | |
关键词: Light Sources; 43 Particle Accelerators; 42 Engineering; Vacuum Systems; Linear Accelerators; | |
DOI : 10.2172/889436 RP-ID : UCRL-TR-221253 RP-ID : W-7405-ENG-48 RP-ID : 889436 |
|
美国|英语 | |
来源: UNT Digital Library | |
![]() |
【 摘 要 】
The vacuum system of the injector for the Linac Coherent Light Source (LCLS) has been analyzed and configured by the Lawrence Livermore National Laboratory's New Technologies Engineering Division (NTED) as requested by the SLAC/LCLS program. The vacuum system layout and detailed analyses for the injector are presented in this final design report. The vacuum system was analyzed and optimized using a coupled gas load balance model of sub-volumes of the components to be evacuated.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
889436.pdf | 2199KB | ![]() |