| USE OF COUPLED MULTI-ELECTRODE ARRAYS TO ADVANCE THE UNDERSTANDING OF SELECTED CORROSION PHENOMENA | |
| Budiansky, N.D. ; Bocher, F. ; Cong, H. ; Hurley, M.F. ; Scully, J.R. | |
| United States. Department of Energy. Yucca Mountain Project Office. | |
| 关键词: Corrosion; Cathodes; Anodes; 36 Materials Science; Kinetics; | |
| DOI : 10.2172/884960 RP-ID : NA RP-ID : NA RP-ID : 884960 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
The use of multi-coupled electrode arrays in various corrosion applications is discussed with the main goal of advancing the understanding of various corrosion phenomena. Both close packed and far spaced electrode configurations are discussed. Far spaced electrode arrays are optimized for high throughput experiments capable of elucidating the effects of various variables on corrosion properties. For instance the effects of a statistical distribution of flaws on corrosion properties can be examined. Close packed arrays enable unprecedented spatial and temporal information on the behavior of local anodes and cathodes. Interactions between corrosion sites can trigger or inhibit corrosion phenomena and affect corrosion damage evolution.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 884960.pdf | 12048KB |
PDF