【 摘 要 】

The purpose of this test was to determine the signal strength and resolution losses of a magnetostrictive ultrasonic system with an extended signal cable. The cable of interest carries electrical signals between the pulse generator/receiver and the magnetostrictive transducer. It was desired to determine the loss introduced by different lengths of the signal cable (6', 100', and 200').