| Radically New Adsorption Cycles for Carbon Dioxide Sequestration | |
| Ritter, James A. ; Ebner, Armin D. ; McIntyre, James A. ; Reynolds, Steven P. ; Gadre, Sarang A. | |
| University of South Carolina | |
| 关键词: Desorption; Materials Recovery; Absorption; Carbon Dioxide; Simulators; | |
| DOI : 10.2172/862198 RP-ID : none RP-ID : FG26-03NT41799 RP-ID : 862198 |
|
| 美国|英语 | |
| 来源: UNT Digital Library | |
PDF
|
|
【 摘 要 】
In Parts I and II of this project, a rigorous pressure swing adsorption (PSA) process simulator was used to study new, high temperature, PSA cycles, based on the use of a K-promoted HTlc adsorbent and 4- and 5-step (bed) vacuum swing PSA cycles, which were designed to process a typical stack gas effluent at 575 K containing (in vol%) 15 % CO{sub 2}, 75% N{sub 2} and 10% H{sub 2}O into a light product stream depleted of CO{sub 2} and a heavy product stream enriched in CO{sub 2}. Literally, thousands (2,850) of simulations were carried out to the periodic state to study the effects of the light product purge to feed ratio ({gamma}), cycle step time (t{sub s}) or cycle time (t{sub c}), high to low pressure ratio ({pi}{sub T}), and heavy product recycle ratio (R{sub R}) on the process performance, while changing the cycle configuration from 4- to 5-step (bed) designs utilizing combinations of light and heavy reflux steps, two different depressurization modes, and two sets of CO{sub 2}-HTlc mass transfer coefficients. The process performance was judged in terms of the CO{sub 2} purity and recovery, and the feed throughput. The best process performance was obtained from a 5-step (bed) stripping PSA cycle with a light reflux step and a heavy reflux step (with the heavy reflux gas obtained from the low pressure purge step), with a CO{sub 2} purity of 78.9%, a CO{sub 2} recovery of 57.4%, and a throughput of 11.5 L STP/hr/kg. This performance improved substantially when the CO{sub 2}-HTlc adsorption and desorption mass transfer coefficients (uncertain quantities at this time) were increased by factors of five, with a CO{sub 2} purity of 90.3%, a CO{sub 2} recovery of 73.6%, and a throughput of 34.6 L STP/hr/kg. Overall, this preliminary study disclosed the importance of cycle configuration through the heavy and dual reflux concepts, and the importance of knowing well defined mass transfer coefficients to the performance of a high temperature PSA process for CO{sub 2} capture and concentration from flue and stack gases using an HTlc adsorbent. This study is continuing.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| 862198.pdf | 507KB |
PDF